(1) Subject to subsection (3), in relation to each control device used, every person referred to in section 4 must prepare and implement an inspection and maintenance plan requiring an inspection at least every three months to verify that
(a) the control device’s internal and external surfaces and its external components, including its control panel, are free from any fracture or deformation;
(b) the ductwork between the control device and any tank does not leak and is not broken;
(c) the filtering media within the control device are free of any blockage and there is no buildup that would affect the operation of the device; and
(d) there are no visible signs of hexavalent chromium compounds at the exit of the control device.
(2) In relation to each control device used with a composite mesh pad system, the inspection and maintenance plan must also include the following tasks:
(a) verifying that there is no buildup on the mesh pads; and
(b) if the mesh pads are not continuously washed, washing the mesh pads for at least 20 minutes
(i) if the manufacturer’s recommendations provide for less frequent washing than twice during every eight hours of operation, in accordance with the manufacturer’s recommendations, or
(ii) in any other case, at least twice during every eight hours of operation with an interval of at least three hours between washes.
(3) If a point source is being used to control the release of hexavalent chromium compounds from a tank located at a facility at which chromium electroplating, chromium anodizing or reverse etching is carried out on the day on which this section comes into force, subsection (1) applies 30 months after that day.
(4) Every person implementing the inspection and maintenance plan must
(a) if they identify any defect in the course of implementing the plan, cease any chromium electroplating, chromium anodizing or reverse etching, correct the defect and verify that the defect has been corrected before resuming any of those activities; and
(b) keep a record that contains the following information:
(i) the date on which each inspection and maintenance task was performed,
(ii) a description of each inspection and maintenance task performed,
(iii) the date on which each defect was identified, and
(iv) a description of the measures taken to correct the defect.