Class II Nuclear Facilities and Prescribed Equipment Regulations, SOR/2000-205

Section 18

Cite as Class II Nuclear Facilities and Prescribed Equipment Regulations, SOR/2000-205, s. 18 · current to September 29, 2025 · regulation last amended September 26, 2025

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) Every licensee who uses, decommissions or services Class II prescribed equipment shall make available to each worker a radiation survey meter that (a) has been calibrated within the 12 months preceding its use; (b) is capable of measuring the gamma, X-ray and, if applicable, neutron radiation from the sealed source and the Class II prescribed equipment; and (c) indicates whether the power level of its batteries is sufficient for its operation. (2) No person shall use, for the purposes of the Act, the regulations made under the Act or an order or a licence, a radiation survey meter that has not been calibrated within the 12 months preceding its use.
Read the Class II Nuclear Facilities and Prescribed Equipment Regulations on the Justice Laws Website ↗

Made under Nuclear Safety and Control Act, S.C. 1997, c. 9.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.