Propane Dispenser Specifications, SI/91-110

Section 6

Cite as Propane Dispenser Specifications, SI/91-110, s. 6 · current to July 24, 2025 · regulation last amended March 22, 2006

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) The temperature sensor of the electronic ATC and the test thermal well of a propane dispenser shall be installed adjacent to each other (a) in the meter chamber; (b) in the vapour separator housing; or (c) in the inlet or outlet piping to the meter. (2) A temperature sensor referred to in subsection (1) shall be installed so that (a) the sensing end of the sensor is in the main flow of liquid; (b) the sensor is located no more than 0.5 m from the meter as measured along the piping; and (c) no valves, pumps, flow-control valves or other equipment that may alter the temperature of the liquid are located between the meter chamber and the sensor.
Read the Propane Dispenser Specifications on the Justice Laws Website ↗

Made under Weights and Measures Act, R.S.C. 1985, c. W-6.