The text
Where a control console for motor fuel dispensers is used with a register so that a person can preset the money value of the liquid to be delivered, the dispenser shall stop the flow of liquid so that the money value registered at the dispenser is not less than the preset value and does not exceed the preset value by more than an amount, rounded up to the nearest cent, equal to five times the applicable minimum increment of registration set out in section 20.
Read the Electronic Registers and Ancillary Equipment Incorporated in Metering Assemblies Specifications on the Justice Laws Website ↗
Made under Weights and Measures Act, R.S.C. 1985, c. W-6.