Electronic Registers and Ancillary Equipment Incorporated in Metering Assemblies Specifications, SI/90-156

Section 14

Cite as Electronic Registers and Ancillary Equipment Incorporated in Metering Assemblies Specifications, SI/90-156, s. 14 · current to July 24, 2025 · regulation last amended March 22, 2006

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

A register shall be designed so that it automatically locks the register display and causes the liquid flow to stop where, during a delivery, false or missing pulses are detected that represent a quantity of liquid in excess of an amount that is the greater of (a) five times the applicable minimum increment of registration set out in section 20, and (b) one increment for every 1,000 increments registered during the delivery.