(1) A register, other than a non-resettable register, that incorporates an electronic display shall
(a) automatically supply electrical power to all display segments for at least 0.5 seconds and cut the power for at least 0.5 seconds after the register is reset to zero and before the next delivery is started, to allow an operator to detect any fault in a segment or in a circuit of the segment; or
(b) incorporate an automatic self-testing system that checks the operation of all display segments prior to starting a delivery and, where a fault is detected, prevents the delivery.
(2) Subsection (1) does not apply in respect of secondary registers that display the same information as the primary register.