Metering Assemblies Incorporating Electronic ATCs Specifications, SI/90-155

Section 23

Cite as Metering Assemblies Incorporating Electronic ATCs Specifications, SI/90-155, s. 23 · current to July 24, 2025 · regulation last amended June 17, 2019

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

A temperature sensor that is used with an ATC shall be located no more than 1 m from the meter, as measured along the piping of the meter, and shall be installed so that (a) the sensing end of the sensor is near the axis of the pipe carrying the liquid; and (b) no valves, pumps or other equipment that may alter the temperature of the liquid are located between the sensor and the meter.
Read the Metering Assemblies Incorporating Electronic ATCs Specifications on the Justice Laws Website ↗

Made under Weights and Measures Act, R.S.C. 1985, c. W-6.