The text
A register incorporating an ATC shall be designed to indicate the density or cubical coefficient of thermal expansion per degree Celsius of the liquid for which it is designed to be used or, if it is designed to be used for more than one liquid, the range of densities or cubical coefficients of thermal expansion per degree Celsius over which it is designed to be used, and the density or cubical coefficient of thermal expansion per degree Celsius to which it is adjusted, by one or more of the following means:
(a) applying a permanent marking in a legible and visible manner on the name-plate of the register;
(b) applying a permanent marking in a legible and visible manner on a metal tag affixed to the register;
(c) legibly displaying or printing the data on demand;
(d) using codes or legends associated with switch settings or jumper locations; or
(e) using any other means of ready access that indicates the data as clearly as the means set out in paragraphs (a) to (d).
Read the Metering Assemblies Incorporating Electronic ATCs Specifications on the Justice Laws Website ↗
Made under Weights and Measures Act, R.S.C. 1985, c. W-6.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.