The text
(1) Every local standard described in column I of the table to this subsection shall be calibrated and certified at least once within the period set out in column II.TABLEItemColumn IColumn IILocal StandardPeriod1A weight, other than a weight referred to in items 2 to 4, that is used by an inspector in examining devices for use in trade 1 year2A weight that is retained in one location and that is used exclusively in examining discontinuous totalizing weighing systems at that location 5 years3A weight, other than a troy weight, that is retained at a Measurement Canada office 5 years4A troy weight that is retained at a Measurement Canada office 10 years5A static volumetric measure other than a measure described in item 6 1 years6A static volumetric measure that is made of glass 10 years7A stoppered pycnometer standard 10 years8A volumetric liquid measuring machine, other than a volumetric liquid meter, that has a valve or any other moving or movable part that has or can have an effect on the accuracy of the machine 4 years9A volumetric standard not otherwise provided for in this table 2 years10A linear static measure 10 years11A standard of temperature(a) of the glass capillary type 10 years(b) of any other type 2 years12A standard of density of the pressure hydrometer type 10 years13A standard of electricity measuring watt hours 1 years14A standard of electricity measuring volt ampere hours 1 years15A standard of electricity measuring var hours 1 years16A standard of electricity measuring amperes rms 5 years17A standard of electricity measuring volts rms 5 years
(2) Where the tolerance for a local standard is that referred to in subsection 54(4), every local standard described in column I of the table to this subsection shall be calibrated and certified at least once within the period set out in column II.TABLEItemColumn IColumn IILocal StandardPeriod1Any electricity measuring standard not specified in subsection (1) 1 years2Any gas measuring standard not specified in subsection (1) 2 years
Read the Weights and Measures Regulations on the Justice Laws Website ↗
Made under Weights and Measures Act, R.S.C. 1985, c. W-6.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.