Weights and Measures Regulations, C.R.C., c. 1605

Section 325

Cite as Weights and Measures Regulations, C.R.C., c. 1605, s. 325 · current to July 24, 2025 · regulation last amended September 20, 2024

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) Subject to subsection (5), when a measuring tank is tested for acceptance limits of error using a known test volume determined in relation to a relevant local standard and set out in Column I of an item of a table to subsection (3) or (4), the measuring tank is within the acceptance limits of error in respect of that known test volume if the actual volume of the measuring tank (a) does not exceed the test volume by an amount in excess of the amount set out in Column II of that item; and (b) is not less than the test volume by an amount in excess of the amount set out in Column II of that item. (2) Subject to subsection (5), when a measuring tank is tested for in-service limits of error using a known test volume determined in relation to a relevant local standard and set out in Column I of an item of a table to subsection (3) or (4), the measuring tank is within the in-service limits of error in respect of that known test volume if the actual volume of the measuring tank (a) does not exceed the test volume by an amount in excess of the amount set out in Column III of that item; and (b) is not less than the test volume by an amount in excess of the amount set out in Column III of that item. (3) Subject to subsection (5), the limits of error set out in the table to this subsection apply to all measuring tanks that are calibrated in terms of metric units of volume.TABLEItemColumn IColumn IIColumn IIIKnown Test VolumeAcceptance Limits of ErrorIn-Service Limits of ErrorLitresMillilitresMillilitres1 50185185210030030032005005004Over 200¼% of known test volume¼% of known test volume (4) Subject to subsection (5), the limits of error set out in the table to this subsection apply to all measuring tanks that are calibrated in terms of Canadian units of volume.TABLEItemColumn IColumn IIColumn IIIKnown Test VolumeAcceptance Limits of ErrorIn-Service Limits of ErrorGallonsFluid OuncesFluid Ounces11066220101035020204Over 50¼% of known test volume¼% of known test volume (5) The limits of error for a measuring tank that is designed for use in measuring liquefied gases are twice the applicable limits of error set out in the table to subsection (3) or (4). (6) The limits of error set out in the tables to subsections (3) and (4) refer to the total inaccuracy of measurement by the measuring tank, including errors due to entrapment of air or liquid by parts of the measuring tank or its associated piping, equipment or accessories during filling or emptying.
Read the Weights and Measures Regulations on the Justice Laws Website ↗

Made under Weights and Measures Act, R.S.C. 1985, c. W-6.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.