When the indicator of an electronic machine, other than an electronic computing machine, is connected to two or more weighing locations, each of which may consist of one or more load-receiving elements, (a) the indicator shall be equipped with a separate calibrating circuit for each weighing location, so that the adjustment of one circuit will not affect the calibration of any other; (b) each calibrating circuit shall be marked to identify which weighing location it controls and that indication shall be clearly visible by any party to the transaction for which the machine is being used; (c) the indicator shall be equipped with an automatic means to clearly identify any weighing location that is in use; and (d) any interconnecting cable that may affect the calibration shall be identified to indicate the weighing location to which it is connected.