Weights and Measures Regulations, C.R.C., c. 1605

Section 179

Cite as Weights and Measures Regulations, C.R.C., c. 1605, s. 179 · current to July 24, 2025 · regulation last amended September 20, 2024

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) When a load remains on an electronic machine, the difference between the indication that is obtained at the moment that the load is applied and the indication that is obtained eight hours after its application shall not exceed the permissible acceptance limit of error for the applied load. (2) The variation on returning to zero after the removal of a load which has remained on an electronic machine for half an hour may not exceed one half the value of the minimum increment of registration. (3) The weight indication at zero or near zero on an electronic machine shall not vary by more than the value of the minimum increment of registration for a difference in ambient temperature of 5°C.
Read the Weights and Measures Regulations on the Justice Laws Website ↗

Made under Weights and Measures Act, R.S.C. 1985, c. W-6.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.