Canada Oil and Gas Drilling and Production Regulations, C.R.C., c. 1517

Section 79

Cite as Canada Oil and Gas Drilling and Production Regulations, C.R.C., c. 1517, s. 79 · current to July 24, 2025 · regulation last amended March 22, 2006

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) All electrical installations at or within 75 feet of any drilling rig, well, separator, crude petroleum storage tank or other unprotected source of ignitable vapours shall be in accordance with the standards prescribed by the Canadian Electrical Code, except where those standards do not conform with the provisions of these Regulations. (2) In lighting installations (a) all wiring shall be in (i) rigid, threaded and vapour-proof conduit with threaded vapour-proof fittings, or (ii) assemblies of type S cord with vapour-proof fittings approved by the Oil Conservation Engineer; (b) all switching and overcurrent protection shall be enclosed in a vapour-proof cabinet with all conductor raceways entering the cabinet properly sealed; (c) all extension cords shall be so connected that accidental disconnection is impossible and when cord receptacle of the lock and switch type are not provided, instructions shall be issued to turn off the current before connecting or disconnecting extension cords; (d) all lamps shall be provided with guards approved by the Oil Conservation Engineer; and (e) all service conductors shall be enclosed in rigid, threaded and vapour-proof conduit or lead-covered or aluminum-covered cable extending at least 75 feet horizontally from any drilling rig, well, separator, crude petroleum storage or other unprotected source of ignitable vapours. (3) In power installations (a) all wiring shall be in (i) rigid, threaded and vapour-proof conduit or lead covered armoured cable or aluminum-covered armoured cable, or (ii) assemblies of type S cable with vapour-proof fittings if approved by the Oil Conservation Engineer; and (b) all switches, control and overcurrent protective devices shall be of a vapour-proof type if fitted inside a derrick or derrick building or within 75 feet of any well, separator, crude petroleum storage or other unprotected source of ignitable vapours. (4) Electric generators, motors and heaters within 75 feet of a drilling rig or well or of equipment in which ignitable vapours are contained shall be of totally enclosed construction. (5) Electrical installations shall be properly maintained at all times.
Read the Canada Oil and Gas Drilling and Production Regulations on the Justice Laws Website ↗

Made under Territorial Lands Act, R.S.C. 1985, c. T-7.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.