The text
(1) Subject to section 128, every window frame and sidelight frame shall have a strength appropriate to the strength of the bulkhead to which it is fastened and shall be fitted
(a) in the case of a window, with toughened glass of an approved thickness, but in no case less than 6 mm thick; and
(b) in the case of a sidelight, with glass of an approved thickness.
(2) Subject to subsection (3), at least one window or sidelight that opens to give a clear opening of not less than 460 mm shall be provided in every fully enclosed cabin, messroom, galley or other accommodation space on or above the main deck that has only one crew access opening, and an exterior hand bar shall be fixed over each such window or sidelight.
(3) Where during the normal operation of a ship a window or sidelight fitted in the side of a superstructure of the ship might be in contact with another ship, no window or sidelight is required to be provided in that side of the superstructure.
(4) Subject to subsection (5), no window shall be located so that the bottom of the aperture, if the window opens, or the bottom of the glass aperture, if the window does not open, is less than 610 mm above the main deck or forecastle deck, as the case may be.
(5) The bottom of every window located in the bow section, other than a wheelhouse window, shall be not less than 2.75 m vertically above the weather deck at that location.
(6) At least one sliding window that gives a clear opening of not less than 560 mm shall be provided on each side of every wheelhouse, unless the wheelhouse has more than one exterior crew access opening and the provision of such a sliding window is not practicable.
(7) No sidelight shall be located below the main deck.
(8) Every sidelight in a structure set on the main deck or a forecastle deck that
(a) can be opened, or
(b) has a glass aperture of more than 250 mm in diametershall be so located that the bottom of the aperture, if the sidelight opens, or the bottom of the glass aperture, if the sidelight does not open, is at least 610 mm above the main deck or forecastle deck, as the case may be.
(9) Every sidelight in the bow section shall be fitted with an internal hinged deadlight.
(10) Every sidelight not in the bow section shall be fitted with an internal shutter attached to the frame by a keep chain or an internal hinged deadlight.
(11) Every window, other than a wheelhouse window, in a structure set on the main deck shall be fitted with a permanently attached internal shutter or hinged deadlight.
(12) Every wheelhouse window that faces forward or athwartships shall be provided with a shutter that, if it is not permanently attached, shall be kept readily available.
Read the Hull Construction Regulations on the Justice Laws Website ↗
Made under Canada Shipping Act, 2001, S.C. 2001, c. 26.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.